Stephanie 5 elite texture joanie. Hi Sharon, This should be relatively easy. You have storage heaters that only take in the hear during cheap rate electricity (at times you cannot change - typically between 00:00 and 07:00 but times vary - ask your electricity supplier).
The controls of an electric storage heater normally consist of two dials to be found under a flap on the heater. The input dial, sometimes known as the charge or overnight dial. This control sets the amount of heat to be stored during the night.
It is best to be set on a seasonal basis: medium for autumn/spring, high for winter. If you find that you run out of heat before the end of the day, and the Input is not on maximum, turn it up to store extra for the following day. The Output Dial sometimes known as the room temperature or boost dial.
Storage Heaters Economy 7
This dial controls the amount of warm air or convected heat given out during the day. It opens and closes.
Nov 24, 2014. I have one of these heaters as well. The input/output dials are thermostats. The higher the input dial is set, the more power the heater draws during its charge cycle (ie the 'on' period that is set on your time panel).
Which means a higher daily ration of heat, and a bigger power bill. The higher the output dial is set, the more quickly the heater lets the stored heat out. So the highest setting would give you most of your daily ration of heat during the 'on' period but less heat for the 'off period. While the lowest setting would give you a relatively constant heat output throughout the day. May 20, 2009.
I'm not a heating expert, but according to the information I could find, Economy 7 utilizes cheap electricty at night, during off-peak hours (7 hours) between midnight and 7AM. Economy 7 costs about 4p per unit compared to peak electricity, which is about 10 to 15p per unit.
If you do not have Economy 7, you can request it FREE of charge from your electricity provider. You will either have one meter with two readings or two separate meters. A two tariff electric meter will record the electricity used during off peak times, so it can be billed, separately, at a lower rate.
Creda Storage Heater 79141
If you have two meters, one meter controls on peak daytime electricity and the other controls your night time economy 7 electricity. I would need to know what model Creda heater you have installed in order to determine how energy efficient it may be. I also will need the model so I can determine operating instructions. If you need further assistance, please post back and let me know. I hope this helps. Universal beam autocad blocks downloads.
Sharper brain software. Posted on Nov 15, 2011.
Name and Registered Office: Creda NOBO - a division of the GDC Group, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO30 2DF, United Kingdom. Company No.1313016 EEE Producer Registration Number - WEE/GE0057TS This is an official website of GDC Group Limited. The GDC Group manages the Creda Heating and NOBO Heating brands.